Panchkula, Haryana
GST No. 06HNNPK5622P1Z9
Call 08048988501 77% Response Rate
Minimum Order Quantity: 1 Unit
Wavelength Range | 325-1000 nm |
Optical System | Single Beam |
Mobility | Benchtop |
Brand | Sky Technology India |
Model No / Item Code | STI 730 |
Photometric Range | -0.3-3A,0-200%T |
Grating | 1200 lines Grating |
Data Output Port | USB Port &Parallel Port (Printer) |
Display | LCD |
Dimensions | 420*280*180 mm |
Light Source | Tungsten Lamp |
Output | USB Port/ parallel Port (Printer ) |
Path Length | 4- Position 10 mm Cell Holder |
Wavelength Repeatability | +/- 0.5 %T |
Material | ABS |
Power Requirement | AC 220 V 50 Hz |
Wavelength Accuracy | +/- 1 nm |
Stray Light | <=0.3%T |
Stability | +/- 0.002 A/h 500 nm |
Weight | 10 Kg |
Detector | Silicon Photo Diode |
Band Width | 2 mm |
Size | 420*280*180 mm |
Applications
Pharmaceutical Industry* Environment Monitoring* Commodity Inspection* Food Inspection* Agricultural Chemistry* Teaching in Colleges & Universities* Metallurgy* Geology* Machine Manufacturing* Petrochemical Industries* Water and waste water Labs* Food and Beverages Labs
Salient Features:
multiple results readout
can display wavelenth ,absorption and transmittance with 5 rusult per screen . it also has a memory store of up to 200 result .memory store upto 200 result .
auto setting wavelenth
users set wavelenth autometeclly throught arrow keys to avoid opretion errors .
2.5 LCD screen
equipped with a 2,5 LCD screen to give a clear display of standrad curves and grups of resutls
technical specification
optical system ; single beam ,grating lines /mm
wavelenght range ; 325- 1000nm
bandwidth ; 2 nm
wavelenght accuracy ; +/- 1 nm
wavelength repeatability ; +/- 0.5 nm
wavelength setting ; auto
photometric accuracy ; +/- 5%T
photometric repeatabilty ; +/- .3 %T
photometric range ; -0.3-3A,0-200%T
stray light ; stability ; +/- 0.002A/h 500 nm
display ; LCD
detector ; silicon photo diode
standrad cell holder ; 4 position 10 mm cell holder
light source ; tungsten lamp
output ; USB port (printer )
power supply ; AC/220V 50Hz
dimension ; 420*280*180 mm
weight ; 10kg
standrad acessories
spectrophotometer ; 1 no.
10 mm glass cuvette ; 4 no.
power cord 1 no.
instruction manual 1no.
software yes
dust cover 1 no.
Additional Information:
View Complete details
Minimum Order Quantity: 1 Unit
Wavelength Range | 325-1000 nm |
Optical System | Single Beam |
Mobility | Benchtop |
Brand | Sky Technology India |
Model No / Item Code | STI 722 |
Cell Holder | 10 mm |
Dimensions | 56*48*29 cms |
Path Length | 10 mm |
Wavelength Repeatability | 1 nm |
Material | ABS |
Power Requirement | 220 V AC |
Wavelength Accuracy | 2 nm |
Stray Light | <0.5%(at 360nm,NaNO2) |
Weight | 11,5 Kg |
Size | 56*48*29 cms |
Applications* Medical/pharmaceutical* Industry environmental Monitoring* Commodity Inspection* Food Inspection* Agricultural Chemistry* Teaching in Colleges & Universities* Metallurgy* Geology* Machine Manufacturing* Petrochemical Industries*Water and Waste water Labs* Food and Beverage Labs
*Design & specification are subject to change without any prior notice.*OEM option available
CHARACTERISTICS* The monochromator with a holographic flashing grating is used.It has the advantage of high wavelength precision, goog monochromaticity and low stray light.* A sample compartment for 0.5cm - 10cm cells.* Computer control system, precise automatic T/A changeover.* Automatic zero and full scale adjustment.* Direct concentration read-out and concentration factor setting function.3* Equipped with Rs232 Port. Data can be sent to PC special software.
Wavelength Range 325 - 1000nmWavelength Accuracy SPECIFICATIONS
VisibleSpectrophotometermodelsare designed for reliablecontinuous operation.It is easy to use,thoroughly reliable andabove all low cost.
Main Instrument 1 unitOperational Manual 1 pcGlass cell 10 mm 4 PcsPower Cable 1 pcFuse(3A) 2 PcsSoftware CD 1 no.Rs232 Cble 1 no.
STANDARD CONFIGURATION OPTIONAL ACCESSORIES*5/10/20/50MMGlass Cell* 50 mm Cell holder*100 mm Cell holder* Tungsten-halogen lamp (12V
Additional Information:
View Complete details
Optical System | Single Beam |
Mobility | Benchtop |
Brand | Sky technology india |
Model No / Item Code | STI 294 |
Display | Digital |
Usage / Application | Laboratory Use |
View Complete details
Minimum Order Quantity: 1 Unit
Wavelength Range | 195-1020 nm |
Mobility | Benchtop |
Brand | Sky Technology India |
Model No / Item Code | STI 285 |
Display | 4 LCD |
Dimensions | 590*460*220 mm |
Wavelength Repeatability | 1 nm |
Material | ABS |
Wavelength Accuracy | +/- 2 nm |
Power Requirement | 220 V/ AC |
Stray Light | <=0.3%T@500 nm |
Stability | +/- 0.004 A/h @500nm |
Weight | 12 Kg |
Size | 590*460*220 mm |
Optical System. | CT grating monochromator |
Applications* Medical/pharmaceutical* Industry environmental Monitoring* Commodity Inspection* Food Inspection* Agricultural Chemistry* Teaching in Colleges & Universities* Metallurgy* Geology* Machine Manufacturing* Petrochemical Industries* Water and Waste water Labs* Food and Beverage Labs
Technical Parameters:
Optical system: CT grating monochromator
Wavelength range: 195 nm-1020nm
Wavelength accuracy: +/-2nm
Spectral bandwidth; 2 nm
Wavelength repeatability: 1 nm
Stray light: Photometric accuracy: +/- 0.5%T
Photometric repeatability: 0.2%T
Stability: +/- 0.004 A/h at 500nm
Work Pattern: T, A, C
Display area: 0-200%T,-0.3-3A
Display modes: 4 LCD
Zero setting: automatic
Weight: 12 kg
STANDARD CONFIGURATION
Software RS 232 Cable 1 no.Main Set 1 no.Accessory kit, Including a 4 glass cell 1 no.2 Quartz Cell 1 no.Operating Manual Software Manual 1 no.Software CD 1 no.Power Cable 1 no.
Additional Information:
View Complete details
Model Name/Number | STI 505 RF |
Brand | Sky Technology india |
Usage/Application | sugar tester |
Packaging Type | box |
Measurement BRIX | 0-32 |
Accuracy | 0-32 |
Temperature Range | automatic |
Material Number | STI 505 RF |
Automatic Shut Off | NO |
Battery Type/Life | 72 hours |
Brix Value | 0.02 % |
Dimension | 45*82 |
Measurement Time | 2 Second |
Measuring Range | 0-32 |
Minimum Sample Volume | 2 scale |
Power Supply | battery |
Temperature Compensation | ATC |
Weight | 200 gm |
Country of Origin | Made in India |
Salinity Refractometer Sugar Tester, is good enough to serve for a long time as long as it is well cared. Whether users are checking the \ripeness\ of fruit in the field, verifying product quality after. Using it in a gentle way, avoiding falling, dropping or any kinds of breaks, clean it after using and put it back in the box. The meter is designed for measuring the concentration of sugar solutions and other non-sugar solutions. It is widely applied in measuring soybean milk concentration, sugar manufacturing, food and beverage. Besides, it is also suitable for measuring the concentration of many other sauce products or fruits, such as soybean sauce, ketchup, jam, honey and so on. From fruit planting to sale, it can help to determine the appropriate harvest period and contribute to classifying the sweetness degree. As for other functions, it can be used to control the concentration of various industrial solution. Please Note don't expose the instrument to damp working conditions or immerse the instrument in water. If the instrument becomes foggy, water has entered the body. Erma Metal and Polypropylene Hand Refractometer (20 cm x 8 cm x 20 cm, Black) 0~100 Salinity.
Additional Information:
View Complete details